Rated Voltage(U0/U):
0.6/1kV, 1.9/3.3kV, 3.6/6kV, 3.8/6.6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV, 12.7/22kV, 18/30kV, 19/33kV, 21/35kV, 26/35kV
Section Area:
Min.: 2.5mm
2, Max.: 500mm
2
Standard:
BS 7870-3, BS7870-4, BS 7870 -6, BS7870-7, BS 7870-8
IEC60502, IEC60332, IEC60754
Product Description:
- XLPE insulated PVC sheathed power cable (
XLPE/PVC Cable)
- XLPE insulated steel tape armored PVC sheathed power cable (XLPE/STA/PVC Cable)
- XLPE insulated steel wire armored PVC sheathed power cable (XLPE/SWA/PVC Cable)
- Flame retardant XLPE insulated PVC sheathed power cable (FR/XLPE/PVC Cable)
- Flame retardant XLPE insulated steel tape armored PVC sheathed power cable (FR/XLPE/STA/PVC Cable)
- Flame retardant XLPE insulated steel wire armored PVC sheathed power cable (FR/XLPE/SWA/PVC Cable)
FR – Flame Retardant
Application:
This type of product is used for power transmission and distribution line with voltage rated at 35kV and below. In comparison with PVC Insulated Power Cable, it boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.
For laying indoor, tunnel, underground and canal, for laying in shaft, water under ground and large difference of level.
Sample and Sketch of cable cross section structure

Single Core XLPE Cable non-armored

Three Core XLPE Cable Steel tape Armored

Three Core XLPE Cable Steel Wire Armored
1. Conductor 2. Conductor Screen 3. XLPE insulation 4. Insulation Screen
5. Metal Screen 6. Filler 7. Seperating Sheath(Inner Covering)
8. Armor 9. Outer sheath
Service Conditions And Parameters Of Cable:
The maximum conductor operating temperature: 90℃;
Short Circuit Temperature 250℃Not more than 5 secretary
Environmental Temperature of operating
In air: 40℃, Underground: 25℃
Depth of laying in direct: 80cm
Thermal Resistance of soil: 100℃.cm/W
Environment temperature should be no lower than 0℃ for laying the cable.
D.C Resistance of finished cable at 20℃ per km is not more than the following.
Nominal Cross Section mm2 |
25 |
35 |
50 |
70 |
95 |
120 |
|
Cu core Ω |
0.727 |
0.524 |
0.387 |
0.268 |
0.193 |
0.153 |
|
Al core Ω |
1.20 |
0.868 |
0.641 |
0.443 |
0.320 |
0.253 |
Nominal Cross Section mm2 |
150 |
185 |
240 |
300 |
400 |
500 |
|
Cu core Ω |
0.124 |
0.0991 |
0.0754 |
0.0601 |
0.0470 |
0.0366 |
|
Al core Ω |
0.206 |
0.164 |
0.125 |
0.100 |
0.0778 |
0.0605 |