By line in the process of the Chinese and foreign is peeling bad as well as the causes of conductor adhesion?
(1) the production of extruding head too much pressure will cause peeling bad, as far as possible when extruding avoid stress by using the method of increasing the die aperture. The second water tank from the nose should be as close as possible. The water should be appropriate, maximum achieve rapid cooling. (2) the isolation cause peeling bad bad, win...
long ago
What is the advantage of large cross-section cable application?
(1) the actual cable through the long-term working current, it must be less than or equal to the permitted load current; (2) according to the normal operation of the load current, check the network voltage loss: under normal circumstances should not exceed 7%, fault condition shall not exceed 10%; (3) according to the startup check network voltag...
long ago
Insulation aging and life concept
Insulation performance with irreversible decline occurring in the course of time, called the aging of the insulation. Insulation aging of the form of various aspects, such as the increase of dielectric loss tangent, low breakdown strength, mechanical strength, or other performance. The cause of insulation aging is complex, there is electric...
long ago
Volume resistivity or size of the insulation resistance and insulation resistance measuring the voltage levels are used when the relationship?
measuring insulation resistance, resistance decreases with the increase of test voltage. The higher the voltage, the higher the degree of polarization of the insulating material under test, the movement of ions to the faster, the greater the conductive currents, which will reduce insulation resistance....
long ago
Cable structure including what content?
Cable structure check, usually including conductor structure check, (foreign economic, pitch, monofilament diameter), extruded insulation and the sheath inspection (average thickness, the thinnest point and extruded overseas economic cooperation), and the covering layer of check, such as shielding copper wire or copper strip dimension inspe...
long ago
BV line distance between two full marks have any requirements?
  BV line at the end of a full marks and the distance between the beginning of the next mark less than 275 mm
long ago
The 330kV Sapele- Ughelli transmission line destroyed by the loaded petrol tanker incident.
The Transmission Company of Nigeria (TCN) says it has lost one of its 330kV transmission lines from Sapele to Ughelli in Delta State to a fire incident caused by a petrol tanker at about 9:42am on Sunday, 9th March, 2014. The melting and snapping of all of the line conductors between the two towers caused a loss of balance along the transmission line and th...
long ago
The different between fire flam resistance cable and fire resistance cable
The building power cable is always fire flam resistance power cable, the fire protection system is always use fire resistance power cable. In brief, fire flam resistance power cable is that whose insulation can burning, but when the source of fire is moved, the cable will be self-extinguishing.it may be can’t work when it is burning, but it can s...
long ago
EPR INSULATION CSM SHEATH CABLE
This kind of cable is applicable for transmitting signal, controlling and measuring of electrical applicances and instruments in the power distribution units. And it is used in power stations, nuclear power plant, underground railway, petrochemical factory, channel, tallbuilding and so on. The maximum of allowable long-time working temperature...
long ago
Instrumentation Cable-CY Cables
Instrumentation cable-CY Cables are widely used and popular in the cable market.And for the Instrumentation Cable-CY Cables, CY means Copper wire braid screen between the inner and outer sheath,the covering should not lower than 85% as common. The cable conductor is flexible Copper wires Class 5 according to IEC 60228.We can often known that the in...