sales@zmscable.com

Aerial Bundled Cable with IEC NFC Standard

overhead single core, 2 core, 4 core Aerial Bundled Cable with XLPE insulation

ZMS Cable company mainly provides complete supply services for distributors and suppliers all over the world. Consulting services, purchasing services, transportation services, and after-sales services are included.

Application

To be used at cottages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75℃ for polyethylene insulated conductors or 90℃ for crosslinked polyethylene (XLPE) insulated conductors. The assembled insulated conductor shall be suitable for use in a system having a standard operating voltage not exceeding 600/1000V. The cores of an aerial bundled conductor shall be laid-up with a left-hand lay. The length of lay shall be 55-75 times the diameter of a phase conductor.

Construction

The conductors shall be stranded circular, except where otherwise stated, and shall comply with all the requirements for class 2 compacted stranded circular conductors of IEC60502.

Technical parameters:

(1)Self-supporting

PhasePhasePhaseApprox.Overall DiameterMax. D.C. Resistance of Conductor at 20℃
AAC+UV-XLPECompact ConductorUV-XLPE Insulation  
No.X No.Cross Section of CoresNo.of Al WiresOverall DiameterNormal ThicknessMin.Diameter  
No. X mm2-mmmmmmmmmmohm/km
1 X 1074.051.00.86.056.053.08
1 X 1674.81.20.987.27.201.91
1 X 25761.20.988.48.401.20
1 X 3577.01.41.169.89.800.868
1 X 5078.31.41.1611.111.100.641
1 X 70199.81.41.1612.612.600.443
1 X 951911.61.61.3414.814.800.320
1 X 12019131.61.3416.216.200.253
1 X 1501914.61.81.5218.218.200.206
1 X 1853616.22.01.7020.220.200.164
1 X 2403618.42.21.8822.822.800.125
2 X 1074.051.00.86.0512.103.08
2 X 1674.81.20.987.214.401.91
2 X 25761.20.988.416.801.20
2 X 3577.01.41.169.819.600.868
2 X 5078.31.41.1611.122.200.641
2 X 70199.81.41.1612.625.200.443
2 X 951911.61.61.3414.829.600.320
2 X 12019131.61.3416.232.400.253
2 X 1501914.61.81.5218.236.400.206
2 X 1853616.22.01.7020.240.400.164
2 X 2403618.42.21.8822.845.600.125
3 X 1074.051.00.86.0513.073.08
3 X 1674.81.20.987.215.551.91
3 X 25761.20.988.418.141.20
3 X 3577.01.41.169.821.170.868
3 X 5078.31.41.1611.123.980.641
3 X 70199.81.41.1612.627.220.443
3 X 951911.61.61.3414.831.970.320
3 X 12019131.61.3416.234.990.253
3 X 1501914.61.81.5218.239.310.206
3 X 1853616.22.01.7020.243.630.164
3 X 2403618.42.21.8822.849.250.125
4 X 1074.051.00.86.0514.643.08
4 X 1674.81.20.987.217.421.91
4 X 25761.20.988.420.331.20
4 X 3577.01.41.169.823.720.868
4 X 5078.31.41.1611.126.860.641
4 X 70199.81.41.1612.630.490.443
4 X 951911.61.61.3414.835.820.320
4 X 12019131.61.3416.239.200.253
4 X 1501914.61.81.5218.244.040.206
4 X 1853616.22.01.7020.248.880.164
4 X 2403618.42.21.8822.855.180.125

(2) Phase + Neutral

PhaseNeutralPhaseNeutralApprox.Overall DiameterMax. D.C. Resistance of Conductor at 20℃
AAC+UV-XLPEAAACCompact ConductorUV-XLPE InsulationConductor  
      PhaseNeutral
No.X No.Cross Section of CoresNo.X N.Cross Section of CoresNo.of Al.WireOverall Dia.No.ThicknessMin.No./Dia. of Al Alloy Wire 

No. X mm2No. X mm2-mm   mmMin.No./mm     mmohm/kmohm/km
1 X 161 X 1674.81.20.987/1.7012.301.912.217
1 X 251 X 25761.20.987/2.1014.701.201.393
1 X 351 X 3577.01.41.167/2.5017.300.8681.007
1 X 501 X 5078.31.41.167/3.0020.100.6410.744
1 X 701 X 70199.81.41.167/3.5023.100.4430.514
1 X 951 X 951911.61.61.3419/2.5027.300.3200.371
1 X 1201 X 12019131.61.3419/2.8030.200.2530.294
1 X 1501 X 1501914.61.81.5237/2.2533.950.2060.239
1 X 1851 X 1853616.22.01.7037/2.5037.700.1640.190
1 X 2401 X 2403618.42.21.8861/2.2543.050.1250.145
2 X 161 X 1674.81.20.987/1.7014.041.912.217
2 X 251 X 25761.20.987/2.1016.631.201.393
2 X 351 X 3577.01.41.167/2.5019.510.8681.007
2 X 501 X 5078.31.41.167/3.0022.460.6410.744
2 X 701 X 70199.81.41.167/3.5025.700.4430.514
2 X 951 X 951911.61.61.3419/2.5030.310.3200.371
2 X 1201 X 12019131.61.3419/2.8033.410.2530.294
2 X 1501 X 1501914.61.81.5237/2.2537.550.2060.239
2 X 1851 X 1853616.22.01.7037/2.5041.690.1640.190
2 X 2401 X 2403618.42.21.8861/2.2547.410.1250.145
3 X 161 X 1674.81.20.987/1.7016.151.912.217
3 X 251 X 25761.20.987/2.1019.061.201.393
3 X 351 X 3577.01.41.167/2.5022.320.8681.007
3 X 501 X 5078.31.41.167/3.0025.590.6410.744
3 X 701 X 70199.81.41.167/3.5029.220.4430.514
3 X 951 X 951911.61.61.3419/2.5034.420.3200.371
3 X 1201 X 12019131.61.3419/2.8037.870.2530.294
3 X 1501 X 1501914.61.81.5237/2.2542.560.2060.239
3 X 1851 X 1853616.22.01.7037/2.5047.250.1640.190
3 X 2401 X 2403618.42.21.8861/2.2553.630.1250.145

(3) Phase + Neutral + Service Connection

PhaseNeutralService ConnectionPhaseNeutral    Service ConnectionApprox.Overall Diameter of Bundled Cable
AAC+UV-XLPEAAAC+UV-XLPEAAC+UV-XLPEConductorUV-XLPEConductorUV-XLPECompact ConductorUV-XLPE 
No.X Normal Cross Section of CoresNo.X Normal Cross Section of CoresNo.X Normal Cross Section of CoresNo. of Al. WireOverall Dia.Normal ThicknessNo./Dia. of Al. WireNormal ThicknessNo. of Al. WireOverall Dia.Normal Thickness 
No. X mm2No. X mm2No. X mm2-mmmmmmmmNo./mmmmmmmm
3 X 161 X 501 X 1674.81.27/3.01.474.81.226.2
3 X 251 X 501 X 16761.27/3.01.474.81.228.6
3 X 351 X 501 X 1677.01.47/3.01.474.81.231.4
3 X 501 X 501 X 1678.31.47/3.01.474.81.234
3 X 701 X 501 X 16199.81.47/3.01.474.81.237
3 X 951 X 501 X 161911.61.67/3.01.474.81.241.4
3 X 1201 X 501 X 1619131.67/3.01.474.81.244.2
3 X 161 X 502 X 1674.81.27/3.01.474.81.226.2
3 X 251 X 502 X 16761.27/3.01.474.81.228.6
3 X 351 X 502 X 1677.01.47/3.01.474.81.231.4
3 X 501 X 502 X 1678.31.47/3.01.474.81.234
3 X 701 X 502 X 16199.81.47/3.01.474.81.237
3 X 951 X 502 X 161911.61.67/3.01.474.81.241.4
3 X 1201 X 502 X 1619131.67/3.01.474.81.2


Overhead Cable

There is no news related to this product.

CORPORATE SOCIAL RESPONSIBILITY

ZMS Cable have a wide product scope, includes: Power cables up to 500kV, AAC, AAAC, ACSR conductors, ABC Cable,electric wires, instrument cable, telecommunications cable, Stay wires. With advanced manufacture technology, rich human resource and effective management system, we guarantee all products are manufactured strictly in accordance with GB, IEC, BS, NFC, ASTM, DIN standards,etc. Beyond quality control, ZMS have been trying its best to offer much higher standard of services rather than expected.

The Adjuster
All customised cables designed by our cable engineer will be subject to testing to relevant standards and appropriate performance criteria. Bespoke cable testing will be conducted under our CNAS accreditation where appropriate. Where required by industry or application, we can submit for relevant cable certification and cable approval processes. For more information or to discuss possible custom designed cable solutions, please complete an enquiry form, contact our technical experts on the Technical Hotline +86 (0)371 6782 9333, or email:sales@zmscable.com

The Zms Cable Advantage

You can contact us in the following ways:

email to sales@zmscable.com OR click Inquiry

INQUIRY