To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for PE insulated Conductors or 90°C for crosslinked polyethylene (XLPE)insulated conductors.

Low-voltage lv ABC cable, designed for overhead power lines and room entrance wires with a rated AC pressure of 1kv and below. It has less installation, maintenance, and operating costs, which can achieve greater economic loss and provide higher security and reliability.


The ZMS cable supplier will also prioritize your specific cable needs so that we can provide a professional cable sales representative to customize the right ABC Wire product for you.

We also have a 6.5-35KV Medium Voltage ABC Cable.

Medium voltage ABC overhead cables are widely used in urban, forest, and coastal areas for power grid transformation and are used for overhead power transmission. ZMS’s medium voltage cables are designed to build a more reliable, efficient, and cost-effective system. We evaluate the quality and technical specifications to ensure that our cable systems are adapted to your distribution network standards.

Application:

This is a kind of climate-bearable PVC, HDPE, and XLPE insulated aerial cables of copper core, aluminum core, or aluminum alloy core, suitable for overhead power lines of AC rated voltage Uo/U 0.6/1KV and below.

It is widely used in power transmission lines and electricity distribution lines with various voltage levels because they have such good characteristics as simple structure, convenient installation, and maintenance, and a low-cost large transmission capacity. And they are also suitable for laying across rivers valleys and places where special geographical features exist.

Standard:

IEC 61089, BS 7870, DIN 48201, ASTM B399, BS EN50183, NFC33-209

Construction:

Conductor: copper, aluminum, aluminum alloy

Insulation: PVC, HDPE, XLPE


multi core.png

If you don’t know how to choose the products you need or don’t find the cable type and size you need on this page, don’t worry. Contact us and send us your requirements, and we can help you choose the right cable. 

You can provide us with the following information: cable voltage, conductor material, insulation and sheath material, shield type, armor type, etc. or you can provide us with cable installation environment, application requirements, etc. We will serve you wholeheartedly. ZMS Cable Supplier has many quality certifications: ISO 9000, ISO 9001, ISO14000, ISO14001, ISO18000, CE, IEC, BS, NFC, ASTM, DIN, etc.


Technical parameters:

Table 1 : Technology requirements of copper core ABC insulated cable

Nominal cross-section area of conductor(mm²)Single wire Min. No of conductorConductor O.D.(reference value)/mmNominal thickness of insulation(mm)
1063.81.0
1664.81.2
2566.01.2
3567.01.4
5068.41.4
701210.01.4
951511.61.6
1201813.01.6
1501814.61.8
1853016.22.0
2403418.42.2
The Max. Resistance of conductor at 20°C(Ω/km)The Min, resistance of insulation at rated temperatureBreaking load of single core
Hard copperSoft copper70°C90°CHard copper
1.9061.830.00670.673471
1.1981.150.00650.655486
0.7490.7270.00540.548465
0.5400.5240.00540.5411731
0.3990.3870.00460.4616502
0.2760.2680.00400.4023461
0.1990.1930.00390.3931759
0.1580.1530.00350.3539911
0.1280.1240.00350.3549505
0.10210.09910.00350.3561846
0.07770.07540.00340.3479823

Table 2: Technology requirements of aluminum core, aluminum alloy core ABC insulated cable

No.section area of conductor (mm²)Single wire Min. No Of conductorConductor O.D. (reference value)/mmCable Max. Average outer diameter(mm)




1063.86.5
1664.88.0
2566.09.4
3567.011.0
5068.412.3
701210.014.1
951511.616.5
1201513.018.1
1501514.620.2
1853016.222.5
2403018.425.6
3003020.827.2
4005323.230.7
The Max. Resistance of conductor at 20°C  (Ω/km)The Min. resistance of insulation at rated temperatureBreaking load of single-core
AlumiunmAluminum   alloy70°C90°CAluminumAluminum   alloy
3.083.5740.00670.6716502514
1.912.2170.00650.6525174022
1.201.3930.00540.5437626284
0.8681.0070.00540.5451778800
0.6410.7440.00460.46701112569
0.4430.5140.00400.401035417596
0.3200.3710.00390.391372723880
0.2530.2940.00350.351733930164
0.2060.2390.00350.352103337706
0.1640.1900.00350.352673246503
0.1250.1450.00340.343467960329
0.1000.1160.00330.334334975411
0.07780.09040.00320.3255707100548

Overhead Cable

There is no news related to this product.

CORPORATE SOCIAL RESPONSIBILITY

ZMS Cable have a wide product scope, includes: Power cables up to 500kV, AAC, AAAC, ACSR conductors, ABC Cable,electric wires, instrument cable, telecommunications cable, Stay wires. With advanced manufacture technology, rich human resource and effective management system, we guarantee all products are manufactured strictly in accordance with GB, IEC, BS, NFC, ASTM, DIN standards,etc. Beyond quality control, ZMS have been trying its best to offer much higher standard of services rather than expected.

The Adjuster
All customised cables designed by our cable engineer will be subject to testing to relevant standards and appropriate performance criteria. Bespoke cable testing will be conducted under our CNAS accreditation where appropriate. Where required by industry or application, we can submit for relevant cable certification and cable approval processes. For more information or to discuss possible custom designed cable solutions, please complete an enquiry form, contact our technical experts on the Technical Hotline +86 (0)371 6782 9333, or email:sales@zmscable.com

The Zms Cable Advantage

You can contact us in the following ways:

email to sales@zmscable.com OR click Inquiry

INQUIRY