Welcome to ZMS Cable Email: info@zmscable.com Tel: +86 371-67829-333

300/500V xlPe Insulated armoured Power cable

300/500V xlPe Insulated, armoured lsZH sheathed Power cables (2-4 cores)

 xlPe Insulated armoured Power cable

300/500V xlPeInsulated, armoured lsZH sheathed Power cables (2-4cores)

fTx200 05RZ1MZ1-R (cU/xlPe/lsZH/sWa/lsZH300/500V class 2)

aPPlIcaTIon

The cables are mainly used in power stations,mass transit underground passenger systems,airports, petrochemical plants, hotels, hospitals, and high-rise buildings.

sTanDaRDs

Basic design adapted toBS 6724

fIRe PeRfoRMance

Flame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2;BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NFC32-070-2.1(C2); CEI 20-35/1-2; EN50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation (Vertically-mountedbundled wires & cabletest)EN 60332-3-24 (cat. C);IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C30-004 (cat. F2); NF C32-070- 2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DINVDE 0482-266-2-4
Halogen FreeIEC 60754-1;EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1;BS 6425-1*
No Corrosive Gas EmissionIEC 60754-2;EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2;BS 6425-2*
Minimum Smoke EmissionIEC 61034-1&2;EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No ToxicgasesNES 02-713; NF C 20-454

Note: Asterisk* denotes superseded standard.

VolTaGe RaTInG

300/500V

cable consTRUcTIon

conductor: Plain annealed copper wire,stranded according to IEC 60228 class 2.

Inner sheath(optional): Thermoplastic LSZH Compound.
armouring: Galvanized steel wire.
outer sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1. UV resistance, hydrocarbon resistance, oil resistance, antirodent and antitermite properties can be offered asoption.

coloURcoDe

Insulation colour as per bs7671


With Earth ConductorWithout Earth Conductor
2 Cores-Brown, Blue
3 CoresYellow/Green, Brown,BlueBrown, Grey, Black
4 CoresYellow/Green, Brown,Grey, BlackBrown, Grey, Black, Blue

sheath colour: Black (other colors upon request)

PHysIcal anD THeRMal PRoPeRTIes

Maximum temperature range during operation (xlPe): 90°C Maximum short circuittemperature (5 seconds): 250°C Minimum bending radius: 10 x Overall Diameter

ConductorFTX200 05RZ1MZ1-R




No. of Core XCross SectionNo./Nominal Diameter of StrandsNominal Insulation ThicknessDiameter Under ArmourArmour Wire DiameterNominal Overall DiameterApprox. Weight
Noxmm2No./mmmmmmmmmmkg/km
2x1.57/0.530.506.50.911.2246
2x2.57/0.670.507.30.912.0292
2x4.07/0.850.508.40.913.1360
3x1.57/0.530.506.90.911.6275
3x2.57/0.670.507.80.912.5331
3x4.07/0.850.509.00.913.7413
4x1.57/0.530.507.60.912.3309
4x2.57/0.670.508.60.913.3380
4x4.07/0.850.509.90.914.6479

conductor operating Temperature : 90°C ambient Temperature : 30°C

Voltage Drop (Per amp Per Meter)

Conductor cross-sectional areaTwo-core cables,d.c.Two-core cable,single- phase a.c.Three-orfour core cable, three-phase a.c.
1234
mm2mV/A/mmV/A/mmV/A/m
1.5313127
2.5191916
4.0121210
Next: ... Prev: