Overhead Line wires, whether bare conductors or insulated cables, provide an aerial route for the transmission and distribution of power.
ZMS Cables supplies a comprehensive range of aluminum overhead conductor line wires AAC, AAAC, ACSR, and aerial bundled cables (ABC) for the aerial power cable.
ABC, AAC, AAAC, ACSR Overhead Cable, Cable Aluminium, is aluminum a conductor, Cable Low-Medium Voltage of ZMS Power Cable Company
Primarily used for overhead service drops applications, such as street lighting, outdoor lighting, and temporary construction service.
To be used at voltages of 600v phase-to-phase or less and at aluminum conductor temperatures not to exceed 75℃ for polyethylene(PE) insulated conductors or 90℃ cross-linked polyethylene(XLPE) insulated conductors.
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system. It provides a higher level of safety and reliability and lower power.
AAAC is used as a naked overhead conductor for transmission and distribution lines and a naked overhead conductor for transmission and distribution lines. AAAC is used for bare overhead wires of transmission and distribution lines, whose overhead lines require more excellent mechanical resistance, better corrosion resistance than AAC, and better corrosion resistance than ACSR. The Sag characteristics and strength-to-weight ratios of AAAC were superior to those of AAC/ACSR.
AAC conductor is also known as an aluminum stranded conductor. It is made of electrolytically refined aluminum with a purity of not less than and as low as 99.7%. Aluminum stranded wire is primarily used in urban areas where spacing is short and support points are close together. All aluminum conductors consist of one or more strands of aluminum wire, depending on the length of the wire, which determines its ultimate use. AAC is widely used in coastal areas because of its high corrosion resistance.
Losses and ultimate system economy by reducing installation, maintenance, and operative cost. The overhead line wires are designed for aerial power lines and room entrance wires with AC-rated voltage of 1kV and below.
GB/T12527,1179 ,IEC60502 ,NFC 33-209 ,BS 7870 ,ANSI/ICEA S-76-474 AS/NZS 3560.1 etc.
*ZMS Cable can also design and produce for special application requirements.
Cable Name | Description | Application |
Covered line wire Service drop cable Secondary UD cable | PVC-insulated aerial cables | Foraerialpower transmission application |
PE-insulated aerial cables | ||
XLPE insulated aerial cables | ||
Steel Reinforced Aluminium Wire with XLPE insulated aerial cable | For aerial power transmission application | |
For aerial power transmission applications, able to bear moderate pulling force. |
No. of cores of aluminum power cable: 1, 2, 3, 4, 5, 3+1, 4+1, 3+2
Nominal cross-section(mm2): 10~240
Phase conductors: Round stood or compacted 1350-H19 aluminum power cables or Copper conductor, AAAC, ACSR
Neutral or messenger conductor: Round stood or compacted 6201 aluminum alloy or AAC cable, ACSR
Street lighting conductor: Round stood or compacted Aluminium conductor
Insulation: LDPE, HDPE, XLPE, PVC (UV-resistant)
There is no news related to this product.
ZMS Cable have a wide product scope, includes: Power cables up to 500kV, AAC, AAAC, ACSR conductors, ABC Cable,electric wires, instrument cable, telecommunications cable, Stay wires. With advanced manufacture technology, rich human resource and effective management system, we guarantee all products are manufactured strictly in accordance with GB, IEC, BS, NFC, ASTM, DIN standards,etc. Beyond quality control, ZMS have been trying its best to offer much higher standard of services rather than expected.